網站首頁  ◇  產品展示    ◇  通用色譜柱 ◇   GC-PLOT柱 > Rt®-Alumina BOND/KCl Columns(熔融石英plot柱)

Rt®-Alumina BOND/KCl Columns(熔融石英plot柱)

更新時間:  2017-07-09

產品型號:  

產品報價:  

所  在  地:  北京市朝陽區望京西園222號星源國際D座1503室

產品特點:  The Rt?-Alumina BOND column is stable up to 200 °C. If water is adsorbed on the column, it can be regenerated by conditioning at 200 °C. Full efficiency and selectivity will be restored.

(聯系我們,請說明是在 北京明尼克分析儀器設備中心 上看到的信息,謝謝!)

產品概述

Rt®-Alumina BOND/KCl Columns (fused silica PLOT)

(KCl deactivation)

Guaranteed Reproducibility
Each Rt
®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene.
With our new technology, both Na
2SO4 and KCl are available with the Rt®-Alumina BOND columns.

Similar Phase(s):

GC-Alumina KCl, CP-Al2O3/KCl

catalog #

length

id

df

units

 

19761

30m

0.32mm

5μm

ea.

19762

50m

0.32mm

5μm

ea.

19759

30m

0.53mm

10μm

ea.

19760

50m

0.53mm

10μm

ea.

Showing 1 to 4 of 4 entries

 

1. Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures. 2. Reactivity of aluminum oxide stationary phase is minimized so that column response for polar unsaturates, such as dienes, is optimized. Column sensitivity or response ensures a linear and quantitative chromatographic analysis for these compounds. 3. Strong bonding prevents particle generation. The column can be used in valve switching operations, without release of particles that can harm the injection and detection systems. 4. The Rt®-Alumina BOND column is stable up to 200 °C. If water is adsorbed on the column, it can be regenerated by conditioning at 200 °C. Full efficiency and selectivity will be restored. 5. High capacity and loadability give exceptionally symmetric peaks; ideal for volatile hydrocarbon separations at percent levels, as well as impurity analyses at ppm concentrations.

Guaranteed Reproducibility Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene. Extensive testing assures reproducible retention times and predictable flow behavior column-to-column.

*       Acetylene elutes before C4 hydrocarbons (impurities in butane/isobutane).

*       Methyl acetylene (impurity in 1,3-butadiene) elutes before 1,3-butadiene.

 

 

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7
北京明尼克分析儀器設備中心

北京明尼克分析儀器設備中心

聯系人:薛海玲  電話:010-84723211  郵箱:xuehail@163.com  總部地址:北京市朝陽區望京西園222號星源國際D座1503室

研發中心:北京市平谷區中關村科技園區興谷A區平和街39號院(聯東U谷)22號樓C區

版權所有 © 2025 北京明尼克分析儀器設備中心  總流量:1015011  備案號:京ICP備10037012號-2

管理登陸  網站地圖  技術支持:化工儀器網

主站蜘蛛池模板: 应城市| 清远市| 焦作市| 兴山县| 泗水县| 彝良县| 基隆市| 舞钢市| 万山特区| 孙吴县| 义乌市| 五台县| 凉山| 广平县| 梁河县| 剑阁县| 东乌珠穆沁旗| 高平市| 威海市| 伊金霍洛旗| 灌南县| 余江县| 平阴县| 辽阳县| 房山区| 正定县| 航空| 西丰县| 龙江县| 通城县| 玛曲县| 英吉沙县| 富阳市| 德清县| 乐昌市| 临夏县| 永善县| 兴城市| 柯坪县| 乌鲁木齐县| 鄄城县|